Agritrop
Accueil

Rapid analyses of dry matter content and carotenoids in fresh cassava roots using a portable visible and near infrared spectrometer (Vis/NIRS)

Ikeogu Ugochukwu N., Davrieux Fabrice, Dufour Dominique, Ceballos Hernan, Egesi Chiedozie, Jannink Jean-Luc. 2017. Rapid analyses of dry matter content and carotenoids in fresh cassava roots using a portable visible and near infrared spectrometer (Vis/NIRS). PloS One, 12 (12):e0188918, 17 p.

Article de revue ; Article de revue à facteur d'impact Revue en libre accès total
[img]
Prévisualisation
Version publiée - Anglais
Utilisation soumise à autorisation de l'auteur ou du Cirad.
journal.pone.0188918.pdf

Télécharger (928kB) | Prévisualisation

Quartile : Q1, Sujet : MULTIDISCIPLINARY SCIENCES

Liste HCERES des revues (en SHS) : oui

Thème(s) HCERES des revues (en SHS) : Psychologie-éthologie-ergonomie; Staps

Résumé : Portable Vis/NIRS are flexible tools for fast and unbiased analyses of constituents with minimal sample preparation. This study developed calibration models for dry matter content (DMC) and carotenoids in fresh cassava roots using a portable Vis/NIRS system. We examined the effects of eight data pre-treatment combinations on calibration models and assessed calibrations on processed and intact root samples. We compared Vis/NIRS derived-DMC to other phenotyping methods. The results of the study showed that the combination of standard normal variate and de-trend (SNVD) with first derivative calculated on two data points and no smoothing (SNVD+1111) was adequate for a robust model. Calibration performance was higher with processed than the intact root samples for all the traits although intact root models for some traits especially total carotenoid content (TCC) (R2c = 96%, R2cv = 90%, RPD = 3.6 and SECV = 0.63) were sufficient for screening purposes. Using three key quality traits as templates, we developed models with processed fresh root samples. Robust calibrations were established for DMC (R2c = 99%, R2cv = 95%, RPD = 4.5 and SECV = 0.9), TCC (R2c = 99%, R2cv = 91%, RPD = 3.5 and SECV = 2.1) and all Trans β-carotene (ATBC) (R2c = 98%, R2cv = 91%, RPD = 3.5 and SECV = 1.6). Coefficient of determination on independent validation set (R2p) for these traits were also satisfactory for ATBC (91%), TCC (88%) and DMC (80%). Compared to other methods, Vis/NIRS-derived DMC from both intact and processed roots had very high correlation (>0.95) with the ideal oven-drying than from specific gravity method (0.49). There was equally a high correlation (0.94) between the intact and processed Vis/NIRS DMC. Therefore, the portable Vis/NIRS could be employed for the rapid analyses of DMC and quantification of carotenoids in cassava for nutritional and breeding purposes.

Mots-clés géographiques Agrovoc : Nigéria

Classification Agris : F60 - Physiologie et biochimie végétale
F30 - Génétique et amélioration des plantes
U30 - Méthodes de recherche

Champ stratégique Cirad : Axe 3 (2014-2018) - Alimentation durable

Auteurs et affiliations

  • Ikeogu Ugochukwu N., Cornell University (USA)
  • Davrieux Fabrice, CIRAD-PERSYST-UMR Qualisud (REU)
  • Dufour Dominique, CIRAD-PERSYST-UMR Qualisud (FRA) ORCID: 0000-0002-7794-8671
  • Ceballos Hernan, CIAT (COL)
  • Egesi Chiedozie, NRCRI (NGA)
  • Jannink Jean-Luc, USDA (USA) - auteur correspondant

Source : Cirad-Agritrop (https://agritrop.cirad.fr/588310/)

Voir la notice (accès réservé à Agritrop) Voir la notice (accès réservé à Agritrop)