Agritrop
Accueil

Quantitative PCR cannot be used in diagnosis of Banana streak virus from banana plants with viral integrations. [P25]

Ricciuti Emeline, Noumbissie Touko Guy Blaise, Chabannes Matthieu, Caruana Marie-Line. 2019. Quantitative PCR cannot be used in diagnosis of Banana streak virus from banana plants with viral integrations. [P25]. In : Livre des résumés des 17 ème Rencontres de virologie végétale. INRA, CIRAD, CNRS, SFP, SFV. Aussois : INRA, Résumé, 84. Rencontres de Virologie Végétale (RVV 2019). 17, Aussois, France, 27 Janvier 2019/31 Janvier 2019.

Communication par affiche
[img] Version publiée - Anglais
Accès réservé aux agents Cirad
Utilisation soumise à autorisation de l'auteur ou du Cirad.
ID590981.pdf

Télécharger (456kB) | Demander une copie

Résumé : Banana streak virus (BSV) is a badnavirus infecting Musa species and inducing Banana streak disease, affecting plant growth and fruit production. BSV exists under two forms: episomal and/or integrated in host genome (referred as “endogenous BSV”, eBSV). Among these viral integrations, four BSV species (BSGFV, BSIMV, BSOLV, and BSMYV) are known to induce eBSV-derived infections under biotic and abiotic stresses.My PhD project aims to follow eBSV-derived infections kinetics in interspecific Musa hybrids (hosting eBSV sequences), over an entire crop cycle. I used qPCR as a quantitative tool to compare BSV infection between different samples, and across time. Because sequence similarity between eBSV and BSV overcomes 99%, I used relative quantification between infected and healthy samples of the same banana genotype hosting eBSV. I refer the healthy, viral particles-free samples as “calibrator”. Viral DNA amplification in the calibrator was supposed to be constant, since eBSV DNA matrix is stable. However, I observed significant variability in eBSV-DNA amplification among a large population of calibrators. This might result from transitory eBSV-DNA expresssion, not encaspidated and therefore escaping serological diagnostics.This result makes this “calibrator” system unreliable for a diagnostic purpose of low infections in banana plants having viral integrations, as standard IC-PCR (immune-capture) and RCA methods have shown better sensibility. Nevertheless, I still use this protocol in my experiments for relative quantification analysis by including a “buffer area” on both sides of the amplification baseline, reflecting viral DNA amplification variations I observed.

Auteurs et affiliations

Source : Cirad-Agritrop (https://agritrop.cirad.fr/590981/)

Voir la notice (accès réservé à la Dist) Voir la notice (accès réservé à la Dist)

[ Page générée et mise en cache le 2019-10-04 ]