Agritrop
Accueil

Use of near infrared spectroscopy for the prediction of quality of poultry feeds in East Africa

Bastianelli Denis, Fermet-Quinet Eric, Davrieux Fabrice, Friot Dominique, Hervouet Catherine. 2007. Use of near infrared spectroscopy for the prediction of quality of poultry feeds in East Africa. In : Near infrared spectroscopy : Proceedings of the 12th International Conference, Auckland, New Zealand, 9th - 15th April 2005. Burling-Claridge G.R. (ed.), Holroyd S.E. (ed.), Sumner R.M.W. (ed.). NIRCE. Chichester : IM Publications, 623-625. ISBN 978-0-473-11646-0|978-0-473-11746-7 International Conference on Near Infrared Spectroscopy. 12, Auckland, Nouvelle-Zélande, 9 Avril 2005/15 Avril 2005.

Communication sans actes
[img]
Prévisualisation
Version publiée - Anglais
Utilisation soumise à autorisation de l'auteur ou du Cirad.
document_531004.pdf

Télécharger (340kB) | Prévisualisation

Résumé : A survey on the quality of poultry feeds was run in 7 east African countries (Kenya, Tanzania, Uganda, Ethiopia, Sudan, Eritrea, Burundi). The objective was to provide a reliable overview of poultry feeds available on the local markets in order to advise farmers for feed use, and help feed millers to improve quality of their products. Approximately 400 samples were collected across the countries in order to cover the variability of all commercial feeds available. They corresponded to broiler and layer feeds, and originated from various suppliers and resellers. Chemical analysis of samples was performed on 150-200 samples selected for their spectral representativeness of the whole database (clustering based on neighbourhood distance calculated from principal components). The parameters measured included Dry Matter (DM), Total Minerals (MM), Crude Protein (CP), Crude Fat (CFat), Crude Fibre (CFib) and Starch (ST). The Metabolizable Energy (ME) value was calculated from chemical composition. NIR analysis was performed on the samples used for chemical analyses (grinding with 1 mm sieve). Spectra in diffuse reflectance were measured on a FOSS NIRSystem 6500 spectrometer in small ring cups. Calibration equations were built after mathematical pre-processing of data (SNV and detrend with 2nd derivative of spectra) without visible wavelengths. Partial Least Squares regression (modified PLS in WINISI software) was found to be the most efficient method for calibrations. Equations obtained had SECV (SE of cross-validation) values of 0.43%, 2.0%, 0.61%, 0.39%, 0.43%, 1.3% and 81.3kcal/kg for DM, MM, CP, CFat, CFib, ST and ME respectively. Except for minerals, the performance of equations was satisfactory and allowed an efficient quality control. They were therefore used for the prediction of the chemical composition of samples not analysed with reference methods. It is concluded that NIRS analysis can be efficient to predict chemical composition of poultry feed in east Africa. This efficiency is probably linked to the relatively small number of raw materials used for feed in this region (essentially 10-15 raw materials). In case a feed would include other raw materials, the prediction could fail, but the sample would probably be detected as an outlier by its H (Mahalanobis) distance to the existing database. In that case reference analyses would be performed.

Mots-clés Agrovoc : alimentation des animaux, volaille, composition chimique, valeur nutritive, spectrométrie

Classification Agris : Q51 - Technologie des aliments pour animaux

Auteurs et affiliations

  • Bastianelli Denis, CIRAD-EMVT-UPR Systèmes d'élevage (FRA) ORCID: 0000-0002-6394-5920
  • Fermet-Quinet Eric
  • Davrieux Fabrice, CIRAD-CP-UPR Qualité produits pérennes (FRA)
  • Friot Dominique, CIRAD-EMVT-UPR Systèmes d'élevage (FRA)
  • Hervouet Catherine, CIRAD-EMVT-UPR Systèmes d'élevage (FRA)

Autres liens de la publication

Source : Cirad - Agritrop (https://agritrop.cirad.fr/531004/)

Voir la notice (accès réservé à Agritrop) Voir la notice (accès réservé à Agritrop)

[ Page générée et mise en cache le 2024-03-20 ]