Performances and pollutants analyzes of Solid Recovered Fuel Wood (SRFW) and wood gasification in downdraft reactors

Vonk Gwendal, Houée J.P., Piriou Bruno, Wolbert Dominique, Vaitilingom Gilles. 2017. Performances and pollutants analyzes of Solid Recovered Fuel Wood (SRFW) and wood gasification in downdraft reactors. In : Book of proceedings 4th International Conference: Wastes: Solutions, Treatments and Opportunities. Vilarinho Cândida (ed.), Castro Fernando (ed.), Carvalho Joana (ed.). Guimarães : CVR, 36-38. International Conference Wastes 2017. 4, Porto, Portugal, 25 Septembre 2017/26 Septembre 2017.

Communication avec actes
[img]
Prévisualisation
Version publiée - Anglais
Utilisation soumise à autorisation de l'auteur ou du Cirad.
2017.Vonk.WASTESConference.pdf

Télécharger (309kB) | Prévisualisation

Url - éditeur : https://www.researchgate.net/profile/Catarina-Nobre/publication/320197052_REMEDIATION_OF_A_LANDFILL_LEACHATE_BY_ADSORPTION_USING_ASHES_AND_BIOCHARS_FROM_DIFFERENT_LIGNOCELLULOSIC_RESIDUES/links/59d4aa61aca2721f436fde01/REMEDIATION-OF-A-LANDFILL-LEACHATE-B

Résumé : Solid Recovered Fuel Wood (SRFW) is an ideal wood substitute in downdraft fixed bed air gasification processes: SRFW syngas quality and process performances are equivalent to wood syngas on both pilot and industrial scales. Syngas Low Heating Value (LHV) ranges from 4.7 to 5.0 MJ/Nm3 for SRFW, and from 4.3 to 4.8 MJ/Nm3 for wood. Differences have been found at pilot scale in H2S and NH3 contents: For H2S, SRFW syngas reaches 3 to 10 ppmv while wood syngas ranges from 2 to 5 ppmv. For NH3, SRFW syngas reaches 1,000 to 3,000 ppmv while wood syngas ranges from 370 to 500 ppmv. This could be explained by higher sulfur and nitrogen contents in SRFW compared to wood. At industrial scale SRFW syngas shows higher H2S content than at pilot scale, probably due to a higher char conversion caused by higher temperature.

Mots-clés libres : Solid Recovered Fuels, Gasification, Polutants

Auteurs et affiliations

  • Vonk Gwendal, Enerxyl (FRA)
  • Houée J.P., Enerxyl (FRA)
  • Piriou Bruno, CIRAD-PERSYST-UPR BioWooEB (FRA) ORCID: 0000-0001-5780-3216
  • Wolbert Dominique, ENSCR (FRA)
  • Vaitilingom Gilles, CIRAD-PERSYST-UPR BioWooEB (FRA)

Source : Cirad-Agritrop (https://agritrop.cirad.fr/611179/)

Voir la notice (accès réservé à Agritrop) Voir la notice (accès réservé à Agritrop)

[ Page générée et mise en cache le 2024-12-06 ]