Agritrop
Accueil

Adaptation of latex diagnosis parameters determination using multiplate reader and freeze-drying conservation to support large-scale utilization in rubber plantations

Junaidi Junaidi, Syafaah Afdholiatus, Aji Martini, Ismawanto Sigit, Oktavia Fetrina, Subandiyah Siti, Montoro Pascal, Nuringtyas Tri Rini. 2024. Adaptation of latex diagnosis parameters determination using multiplate reader and freeze-drying conservation to support large-scale utilization in rubber plantations. Trends in Sciences, 21 (9):7963, 15 p.

Article de revue ; Article de recherche ; Article de revue à comité de lecture Revue en libre accès total
[img]
Prévisualisation
Version publiée - Anglais
Sous licence Licence Creative Commons.
Junaidi_2024_Hevea_Latex_Diagnosis.pdf

Télécharger (650kB) | Prévisualisation

Résumé : The Latex Diagnosis (LD) is performed through the determination of dry rubber (DRC), sucrose (Suc), inorganic phosphorus (Pi) and thiol (RSH) contents. It is carried out through the colorimetric method using a single cuvette spectrophotometer, which is time-consuming and requires a high volume of chemicals. It also needs to be executed as soon as the samples are collected so that limits the adoption of LD. The adaptation of the protocol to a multiplate reader and suitable conservation aimed to overcome the limitations. The experiments were carried out at the Indonesian Rubber Research Institute, Sembawa, Palembang, and Research Center for Biotechnology, Universitas Gadjah Mada, Yogyakarta. Various combinations of solution volumes, adapted from standard protocol, were tested. The closest slope of the standard curve to control was then applied to 7 randomly selected trees. The result showed that for Suc, the composition of 10 µL samples, 30 µL of 2.5 % TCA and 210 µL anthrone reagent was suitable for determination using a multiplate reader. The combination of 40 µL of sample, 85 µL of 2.5 % TCA and 125 µL mL FeSO4 solution was suitable for Pi determination, while 100 µL samples, 5 µL DNTB and 100 µL Tris is recommended for RSH. The measurement using a multiplate reader resulted in comparable contents (average deviations were 1.83, 2.69 and 3.51 % for Suc, Pi, and RSH, respectively), lower time and chemicals consumptions, and a larger number of sample handling compared to single cuvette method. This study also tested the effect of freeze-drying for sample conservation. The result indicated that freeze-drying was able to maintain the Pi level (deviation 0.93 %). However, it increased Suc (deviation 19.43 %) and decreased ascorbate (AsA) significantly (deviation 43.60 %); therefore, freeze-drying might not be suitable for conserving serum samples in the LD method.

Mots-clés Agrovoc : latex, Hevea brasiliensis, spectroscopie infrarouge, saccharose, antioxydant, composition chimique, thiol

Mots-clés libres : Latex diagnosis, Surcrose, Inorganic phosphorus, Thiols, Ascorbate, Hevea brasiliensis, Multiplate reader, Freeze-drying

Agences de financement hors UE : Agropolis Fondation, Universitas Gadjah Mada

Projets sur financement : (FRA) Labex AGRO 2011-LBX-002, (FRA) Rubber Redox

Auteurs et affiliations

  • Junaidi Junaidi, IRRI [Indonesian Rubber Research Institute] (IDN) - auteur correspondant
  • Syafaah Afdholiatus, IRRI [Indonesian Rubber Research Institute] (IDN)
  • Aji Martini, IRRI [Indonesian Rubber Research Institute] (IDN)
  • Ismawanto Sigit, CIRAD-BIOS-UMR AGAP (FRA)
  • Oktavia Fetrina, CIRAD-BIOS-UMR AGAP (FRA)
  • Subandiyah Siti, Gadjah Mada University (IDN)
  • Montoro Pascal, CIRAD-BIOS-UMR AGAP (FRA)
  • Nuringtyas Tri Rini, Gadjah Mada University (IDN) - auteur correspondant

Source : Cirad-Agritrop (https://agritrop.cirad.fr/610365/)

Voir la notice (accès réservé à Agritrop) Voir la notice (accès réservé à Agritrop)

[ Page générée et mise en cache le 2024-11-04 ]